NVELOPE fixed point brackets absorb both vertical dead loads.
NVELOPE Bracket spacing is determined by cladding options such as the dimensions and weight of the façade cladding, local wind loads and cladding zone.
![]()
suitable as a back frame system (NV1 is the basis of all NVELOPE rainscreen systems) – NV1 is suitable for face fixing / rivet fixing cladding – elements to (e.g. fibre cement, high pressure laminate (HPL), ACM and metal rainscreen panels.
![]()
manufacturer: NVELOPE rainscreen systems ltd
product reference: NVELOPE NV1
type:
[40]. - adjustment from 42 mm min to 62 mm max – single / double - 6.5 mm holes / 11.0 mm holes*
[60]. - adjustment from 62 mm min to 102 mm max – single / double - 6.5 mm holes / 11.0 mm holes*
[90]. - adjustment from 92 mm min to 132 mm max – single / double - 6.5 mm holes / 11.0 mm holes*
[120]. - adjustment from 122 mm min to 162 mm max – single / double - 6.5 mm holes / 11.0 mm holes*
[150]. - adjustment from 152 mm min to 192 mm max – single / double - 6.5 mm holes / 11.0 mm holes*
[180]. - adjustment from 182 mm min to 222 mm max – single / double - 6.5 mm holes / 11.0 mm holes*
[210]. - adjustment from 212 mm min to 252 mm max – single / double - 6.5 mm holes / 11.0 mm holes*
[240]. - adjustment from 242 mm min to 282 mm max – single / double - 6.5 mm holes / 11.0 mm holes*
[270]. - adjustment from 272 mm min to 312 mm max – single / double - 6.5 mm holes / 11.0 mm holes*
[300]. - adjustment from 302 mm min to 342 mm max – single / double - 6.5 mm holes / 11.0 mm holes*
* 6.5 mm holes (suitable for steel and / or timber substrates) / 11.0 mm holes (suitable for block / concrete substrates)
if isolator is not required reduce dimensions by 5mm
profiles:
[L]. 60 x 40 mm
[T]. 40 x 100 / 60 x 80 / 60 x 120 / 60 x 140 mm
NVELOPE isolators: included as standard
![]()
material:
manufactured from extruded aluminium alloys conforming to EN 573-3 (material) and EN 755 (production).
![]()
NVELOPE brackets (V):
allows adjustment between face of primary support to outer face of vertical profile.
thermal isolators:
hard PVC isolator assembled as standard (located between the NVELOPE bracket and the primary structural support system).
![]()
BBA – 09/4678